Assistenza e riparazione equilibratrici e magnetoscopi Borgo



More than 60 years after the production of the first Borgo dynamic balancing machine and almost 20 years after the sale of our business to another company, the stock of spare parts remaining has almost completely run out.

Among the most requested spare parts are still available the copper contact braids for the supports of the MAB 140 and MAB 200 crack detectors (code MB330100).

 
The sensor coils of the supports of all the soft bearing balancing machines, once produced directly by Borgo, are no longer available and must be regenerated with a new winding made with 1500 turns of 0.04 mm copper wire so as to obtain a resistance of approximately 2200-2300 Ohm.
The wire must be distributed uniformly in the Ø 32.9 mm groove of the coil and must remain under
its external diameter of 34.3 mm.

The C80BK gauges of the ED series dynamic balancing machines with vector screens can currently still be requested from the company that produced them for Borgo.

   The unbalance display modules of the digital instruments of the EDC or
   PHE series are difficult to repair owing to the unavailability of their
   obsolete electronic components,
but it is normally possible to repair the control module
   (the first on the left, whose front panel includes the Storage button) when
   the fault is due to the failure of the voltage regulators of the power supply board, which
                                          are easily replaceable.
                                                       
   The 9" black and white CRT screen of the RB measuring cabinets and the 14" color
    screen of the RM cabinets are no longer available, but they can be replaced with color
    TFT displays of equivalent size.
    The motherboard of the PC integrated into the cabinet usually stops working correctly
    when its battery is empty.
                                           The battery in almost all cards is inserted inside an integrated circuit (Real Time Clock).
    Running out of battery causes the BIOS to return to the default values ??that are not
    suitable for the operation of the balancing software.
    The Real Time Clock can be replaced and by restoring the BIOS parameters with the
    correct values, the system returns to normal operation.
    The values ??of the parameters to be restored can be communicated on request.
                                                              RETROFIT

When the electronic cards of a digital or computerized instrumentation are no longer available, nor can they be repaired due to unavailability of their components, it is possible to replace the instrumentation with a new model corresponding to the current state of the art.
Ask me for information about it.



wholesale china